Wamsler Haus W1-40 Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Cuisiniers Wamsler Haus W1-40. Wamsler Haus W1-40 Technical data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
25
Instructions for Installation and Use
W1-40
E
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1

25 Instructions for Installation and Use W1-40 E

Page 2 - Preface

34 1.7 Chimney attachment The connection for attaching to the chimney must be able to withstand at least 400°C. PLEASE NOTE: Before connecting the s

Page 3

35 1.8.2 Side connection (Fig. 1) • Remove the rear flue outlet (1) by loosening the screws. • Remove the cooking plate (2) and the fire bricks (3

Page 4 - 1.1 Safety measures

36 Action in case of chimney fire! If a chimney is not cleaned often enough, or if the wrong type of fuel is us

Page 5

37 2. Fuels / Settings 2.1 Fuels Low smoke, trouble-free operation of the stove and a supply of heat at the nominal level with a chimn

Page 6

38 2.2 Combustion airflow settings The settings must always be as shown. Fuel Primary airflow setting Start damper setting Secondary airflow settin

Page 7

39 3.1.3 Start damper For lighting the stove the start damper must be open and when cooking or heating it must be closed. 1 - Closed (cooking, b

Page 8

40 3.2 Lighting The performance control is set depending on the type of fuel as a function of the chimney draught and the desired heating level. Wit

Page 9 -

41 3.4 Closing down Close the primary air regulator (Table 2). Let the embers burn out and leave the stove to cool down. Once the stove is cold, emp

Page 10

42 PLEASE NOTE: After every period of heating you should check the stove thoroughly. If repairs or replacements are necessary, please contact your su

Page 11

43 Parts explosion diagram for Chapter 3.6 Care and cleaning: Fig. 4 2 3 1 4

Page 12 - Richtig

______________________________________________________________________ _____________________________________________________________________ 26 Prefac

Page 13

44 3.7 Troubleshooting Your stove has been built using modern technology. Even so, problems can arise, which may derive from the chimney, the fuel o

Page 14

45 4. Technical data 4.1 Data 4.2 Dimensions W1-40 screw feet can raise stove height by +20 mm The dimension information sh

Page 15

46 4.3 EC-Declaration of Conformity WAMSLER Haus- und Küchentechnik GmbH EC-Declaration of Conformity Manufacturer: Wamsler Haus- und Küchentec

Page 16

47 We will only provide a guarantee for equipment which can be shown to have been connected and set up by an approved installer or another recognised

Page 17

48 than the residence or place of work of the recipient are charged to the recipient, unless the delivery was part of the normal use of the item. 5.

Page 18

49 Guarantee card Subject to the conditions stated we offer the following guarantee: 2 Year general equipment guarantee of problem-free functioning

Page 19

27 Table of Contents Preface...26 Table o

Page 20

28 1. Installation 1.1 Safety measures 1. The stoves are tested to EN 12815 (see identification plate). 2. For installation and for flue ga

Page 21

29 the stove is being used. Use the protective gloves or the implements provided. Children and young people under 16 must not use the sto

Page 22

30 1.2 Parts W1-40 Key: Standard accessories: 1. Primary air control - Flue cover 2. Steel plate - Protective gloves

Page 23

31 1.3 Instructions For installation and for connection of flue, the requirements of the Fire Regulations (FeuVO in Germany) apply,

Page 24

32 Important NOTES relevant to operation dependent on air supply from room or independent of air supply from room (valid for Germa

Page 25 - Innovation from Tradition

33 1.6 Safe distances The following distances must be respected as safety margins from flammable objects and bearing walls made of reinforced concre